Promote the "Belt and Road Initiative", reduce the regulatory pressure on the government, save the operating costs of enterprises and facilitate international trade.
Reliability and Key Features
● Rated for -40°C at 32°C ambient
● Rapid cooling with shelf evaporator
● Improved temperature uniformity with dual capillary tube design at the range of-20°C to -40°C
● Improved door seal design with two gaskets maintains cabinet temperature more efficiently
● Reduced frost buildup
● 90mm insulation thickness for additional robustness, less power consumption and better temperature retaining ability
● Drawer design maximizes storage space.One unit can hold 360 bags of 230 ml blood bags
● Optional USB interface
Safety
● Multiple malfunction alarms include high/low temperature,power failure, sensor error,low battery,high ambient temperature
● Two types of alarms: buzzer and flashing light,remote alarm
Ergonomic Design
● LED digital display for clear observation
● Double door design with independent locks reduces air leakage to ensure temperature stability and lower power consumption
● Tracks to label drawers for product identification
Model | DW-40L418D | DW-40L528D | DW-40L528DA | ||
Technical Data | Cabinet Type | Upright (Double Door) | Upright (Double Door) | ||
Climate Class | SN N | SN N | |||
Cooling Type | Direct Cooling | Direct Cooling | |||
Defrost Mode | Manual | Manual | |||
Refrigerant | HC | HC | |||
Sound Level (dB(A)) | 40 | 39 | 42 | ||
Performance | Cooling Performance (°C) | -40 | -40 | ||
Temperature Range (°C) | -20~-40 | -20~-40 | |||
Control | Controller | Microprocessor | Microprocessor | ||
Display | LED | LED | |||
Electrical Data | Power Supply (V/Hz) | 220~240/50 | 220~240/50 | 208~230/60 | |
Power (W) | 370 | 375 | 280 | ||
Dimensions | Capacity (L/Cu.Ft) | 418/14.8 | 531/18.8 | ||
Net/Gross Weight (approx) | kg | 141/169 | 147/178 | ||
lbs | 310.8/372.6 | 324.1/392.4 | |||
Interior Dimension (W×D×H) | mm | 554×620×1230 | 704×620×1230 | ||
in | 21.8×24.4×48.4 | 27.7×24.4×48.4 | |||
Exterior Dimension (W×D×H) | mm | 790×845×1878 | 940×845×1878 | ||
in | 31.1×33.3×73.9 | 37.0×33.3×73.9 | |||
Packing Dimension (W×D×H) | mm | 860×930×2040 | 1005×940×2040 | ||
in | 33.9×36.6×80.3 | 39.6×37.0×80.3 | |||
Container Load (20'/40'/40'H) | 12/24/26 | 10/22/24 | |||
Alarms | High/Low Temperature | Y | Y | ||
Remote Alarm | Y | Y | |||
Power Failure | Y | Y | |||
Sensor Error | Y | Y | |||
Low Battery | Y | Y | |||
High Ambient Temperature | Y | Y | |||
Dirty Condenser | Y | Y | |||
Door Ajar | Y | Y | |||
Accessories | Casters | Y(4) | Y(4) | ||
Leveling Feet | Y(2) | Y(2) | |||
Porthole | Y, 1×Left Side, 1×Right Side, (25mm)Diameter | Y, 1×Left Side, 1×Right Side, (25mm)Diameter | |||
Inner Doors | N | N | |||
Drawers | 12- Plastic Drawers, Optional | 10-Plastic Drawers, Optional | |||
Shelves | 3- Adjustable Wire Shelves | 3- Adjustable Wire Shelves | |||
Shelf Dimensions (W×D)(mm) | 530×528 | 680×537 | |||
Max. Load per Shelf (kg) | 28 | 37 | |||
USB Interface | Optional | Optional | |||
RS485 | Optional | Optional | |||
NFC | N | N | |||
Temperature Recorder | Optional | Optional | |||
Others | Certificate | CE, MDR | CE, MDR | CE, MDR |