Promote the "Belt and Road Initiative", reduce the regulatory pressure on the government, save the operating costs of enterprises and facilitate international trade.
Intelligent Defrosting: Prolongs the Defrosting Cycle, Safeguarding the Stability
of the Storage Temperature
Compared with traditional timed defrosting the intelligent defrosting technology reduces the defrosting frequency by half, effectively draws down the temperature fluctuation caused by defrosting during the sample storage cycle by intelligently identifying the amount of frost on the evaporator.
Dual Independent Refrigeration Systems: Superior Safety
If one system fails, the other one would reach -25°C quickly, which doubles the safety of the sample: With air cooling technology the inside uniformity can reach +3℃(+5°C during the defrosting period).
Advanced Defrosting Technology Optimised Safety
The automatic hot gas defrosting technology eliminates the risk of electrical leakage which can occur with heated wire defrosting techniques.
Green Hydrocarbon Refrigeration
The DW-30L1280F utilises HC refrigeration technology which is energy-efficient and has a zero impact on the ozone layer. The energy consumption of this model is 8kW/24H.
Model | DW-30L520F | DW-30L1280F | |||
Technical Data | Cabinet Type | Upright | Upright (Double Door) | ||
Climate Class | SN N | N | |||
Cooling Type | Forced Air Cooling | Forced Air Cooling | |||
Defrost Mode | Automatic Defrost | Automatic Defrost | |||
Refrigerant | HC | HC | |||
Sound Level (dB(A)) | 44 | 45 | 46 | ||
Performance | Cooling Performance (°C) | -30 | -30 | ||
Temperature Range (°C) | -10~-30 | -10~-30 | |||
Control | Controller | Microprocessor | Microprocessor | ||
Display | LED | LED | |||
Electrical Data | Power Supply (V/Hz) | 220~240/50 | 208~230/60 | 220~240/50 | |
Power (W) | 650 | 495 | 900 | ||
Dimensions | Capacity (L/Cu.Ft) | 520/18.4 | 1280/45.2 | ||
Net/Gross Weight (approx) | kg | 210/252 | 420/480 | ||
lbs | 463.0/555.6 | 925/1057 | |||
Interior Dimension (W×D×H) | mm | 610×755×1006 | 1320×752×1260 | ||
in | 24×29.7×39.6 | 52×29.6×49.6 | |||
Exterior Dimension (W×D×H) | mm | 848×1011×1780 | 1520×1065×1996 | ||
in | 33.4×39.8×70.1 | 59.8×41.9×78.6 | |||
Packing Dimension (W×D×H) | mm | 900×1060×1920 | 1580×1100×2100 | ||
in | 35.4×41.7×75.6 | 62.2×43.3×82.7 | |||
Container Load (20'/40'/40'H) | 10/22/22 | 6/14/14 | |||
Alarms | High/Low Temperature | Y | Y | ||
Remote Alarm | Y | Y | |||
Power Failure | Y | Y | |||
Sensor Error | Y | Y | |||
Low Battery | Y | Y | |||
High Ambient Temperature | Y | Y | |||
Dirty Condenser | Y | Y | |||
Door Ajar | Y | Y | |||
Accessories | Casters | Y(4) | Y(4) | ||
Leveling Feet | Y(2) | Y(2) | |||
Porthole | Y, 1×Left Side, 1×Right Side, (25mm)Diameter | Y, 1×Left Side, 1×Right Side, (25mm)Diameter | |||
Inner Doors | N | N | |||
Drawers | 16/20-Plastic Blood Bag Drawers, Optional | 48- Plastic Blood Bag Drawers, Optional | |||
Shelves | 4- Adjustable Wire Shelves | 12- Adjustable Stainless Steel Shelves | |||
Shelf Dimensions (W×D)(mm) | 580×670 | 569×673 | |||
Max. Load per Shelf (kg) | 39 | 40 | |||
USB Interface | Optional | Y | |||
RS485 | Y | Y | |||
NFC | Optional | Y | |||
Temperature Recorder | Optional | N | |||
Others | Certificate | CE, MDR | / | CE, MDR |
X