English

Promote the "Belt and Road Initiative", reduce the regulatory pressure on the government, save the operating costs of enterprises and facilitate international trade.

5.0 (1 review) 12 sold certified
One-stop and all-round foreign trade services
  • [list:title]
  • [list:title]
  • [list:title]
  • [list:title]
  • [list:title]

Classic Series Biological Safety Cabinet HR30-IIA2/HR40-IIA2

Product Introduction

The Haier Biomedical Biological Safety Cabinet is designed to protect the operator, laboratory environment and samples from being exposed to the infective aerosol produced from samples with bacteria strains, diagnostic materials, and other infective substances. It provides the operator with comfortable and safer working conditions. It is widely used in medical health, disease prevention, food safety, biological pharmacy and environment monitoring.

Classic Series Biological Safety Cabinet HR30-IIA2/HR40-IIA2

Product Introduction

The Haier Biomedical Biological Safety Cabinet is designed to protect the operator, laboratory environment and samples from being exposed to the infective aerosol produced from samples with bacteria strains, diagnostic materials, and other infective substances. It provides the operator with comfortable and safer working conditions. It is widely used in medical health, disease prevention, food safety, biological pharmacy and environment monitoring.

Product description

304 Stainless Steel Operation Platform and Internal Wall

● Stainless steel work surface without screws ensures no accumulation of contaminant

● Removable air in-flow plate is easy to clean and disinfect

● Internal wall is constructed of a single piece stainless steel, with 12mm arc angle corners which allows for more effective cleaning

● The volume of liquid tank is over 4L, equipped with outlet valve for convenient cleaning and maintenance

● Concaved work surface, waste liquid easily collected

● Adjustable stand (0-75mm) without exposed screw thread, reduces risk of contamination

 

Ultra Low Penetration Air Filtration System

● American AAF ULPA filter

● Tested to a typical efficiency of 99.9995% for 0.12 micron particles

● Provides FED STD 209E class 1 (or ISO14644.1 class 3) clean air to work surface in a stable vertical laminar flow to protect samples

● The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection

 

High Efficiency Blower System

● The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance

● Self cooling system reduces energy consumption while enhancing reliability


Parameter

Specifications



Model

HR30-IIA2

HR40-IIA2

General Specification

Power Supply(V/Hz)

220-240/50/60

115/60

220-240/50/60

Power (VA)

1300

1300

1300

Power of Blower (W)

AC 540/625

AC 540/625

AC 540/625

Airflow Circulation

70% Downflow, 30% Exhaust

70% Downflow, 30% Exhaust

70% Downflow, 30% Exhaust

Main Filter Typical Efficiency

ULPA, U15.99.9995% @0.12μm

ULPA, U15.99.9995% @0.12μm

ULPA, U15.99.9995% @0.12μm

Exhaust Filter Typical Efficiency

HEPA, H14.99.995% @0.3μm

HEPA, H14.99.995% @0.3μm

HEPA, H14.99.995% @0.3μm

Exhaust Filter

Single

Single

Single

Filter’s Brand

AirePlus

AAF

AAF

Downflow Velocity (m/s)

0.3

0.28

0.3

Inflow Velocity (m/s)

0.53

0.55

0.53

Lighting Intensity (Lux)

1100

1200

1200

Sound Level (dB(A))

61

64

64

Bench or Stand Only

Stand only

Stand only

Stand only

Dimensions

Net/Gross Weight

kg

220/248

258/305

258/305

lbs

485/546.7

568.8/672.4

568.8/672.4

Internal Dimensions (W*D*H)

mm

900*610*680

1167*610*680

1167*610*680

in

35.4*24.0*26.8

45.9*24.0*26.8

45.9*24.0*26.8

External Dimensions (W*D*H)

mm

1100*820*2200

1360*820*2200

1360*820*2200

in

43.3*32.3*86.6

53.5*32.3*86.6

53.5*32.3*86.6

Packing Dimensions (W*D*H)

mm

1185*945*1750

1445*945*1720

1445*945*1720

in

46.7*37.2*68.9

56.9*37.2*67.7

56.9*37.2*67.7

Support Stand (mm)

680mm (standard).

680-900mm adjustable height (optional)

680mm (standard).

680-900mm adjustable height (optional)

680mm (standard).

680-900mm adjustable height (optional)

Sash Opening (mm)

190 (Max 490)

190 (Max 490)

190 (Max 490)

Container Load (20'/40'/40'H)

10/20/20

8/16/16

8/16/16

Alarms Functions

Alarm

Sound and Flash

Sound and Flash

Sound and Flash

Closing Fan Alarm After Door Opening

Y

Y

Y

Door Ajar

Y

Y

Y

Abnormal Inflow

Y

Y

Y

Abnormal Downflow

Y

Y

Y

Door Open More than Limit

Y

Y

Y

Filter Clogging

Y

Y

Y

Filter Damage

Y

Y

Y

Filter Lifetime Lack

Y

Y

Y

UV Light Lifetime Lack

Y

Y

Y

Accessories

UV Lamp

Y

Y

Y

Socket

1 Socket

1 Socket

1 Socket

Valve Port

Standard with 2 Valve Port

Standard with 2 Valve Port

Standard with 2 Valve Port

Side Wall Service Taps

Standard gas tap and vacuum Tap; optional compressed air tap and water tap

Standard gas tap and vacuum Tap; optional compressed air tap and water tap

Standard gas tap and vacuum Tap; optional compressed air tap and water tap

Antimicrobial Coating

Optional

Optional

Optional

316SS Work Surface

Optional

Optional

Optional

Work Surface

One-piece

One-piece

One-piece

Touch Screen

N

N

N

Motorized Window

N

N

N

Foot Switch

N

N

N

Armrest

Y

Y

Y

Exhaust Dust Connection Kits

Optional

Optional

Optional

Others

Certification

CE, TUV

/

CE, TUV


Get In Touch

X

ogo

Appointment Experience

X